Downlights and ceiling lights: what an electrician does

Last updated

Quick answer: In Malaysia, an electrician fitting downlights checks your ceiling and lighting circuit, agrees positions and switch type, cuts the openings, runs cable, wires the lights through the switch, tests and hands over. Wiring changes go to a contractor registered with the Energy Commission. This page also lists what to tell the electrician before you ask for quotes.

Get quotes
Six numbered steps showing what an electrician does when fitting downlights: look first, agree the plan, cut and run cable, connect, test, hand over
The job in six steps. Diagram: Dispatcher (file). Credit: drawn by Dispatcher, own work, licence held by Dispatcher.

A downlight looks like a small job from the floor. Above the ceiling it is wiring work.

This page explains what the electrician does, which lighting circuit your lights hang on, and what to say before you ask for quotes. It gives no do-it-yourself steps, and it says why.

What does an electrician do when fitting downlights?

A typical job has six steps: look, agree the plan, cut and run cable, connect, test and hand over. That order is Dispatcher's plain summary, not a rule, and your contractor may work in a different order.

The wiring itself is for a registered contractor. Suruhanjaya Tenaga (ST, the Energy Commission) says on its home wiring page that consumers need to contact any electrical contractor registered with the Energy Commission for inspection and internal house wiring work.

  • First, look. The electrician checks your ceiling and the lighting circuit that will feed the new lights. Your DB box is the board that splits your power into circuits.
  • Second, agree the plan. You settle where each light goes and which switch controls it.
  • Third, cut and run cable. The openings are made, then cable runs to each light position.
  • Fourth, connect. The lights are wired to the lighting circuit through the switch.
  • Fifth, test. The electrician switches on and checks that every light works.
  • Last, hand over. You see the switch work and ask about anything unclear.

See our guide to booking an electrician home visit.

You may see other websites give hole sizes, light spacing, wattage and insulation gaps. This page does not. We have no Malaysian source for them, so your electrician decides them for your ceiling.

What lighting circuit sits behind your ceiling lights?

Your ceiling lights hang on a lighting circuit.

Diagram of the path from the DB box through a lighting breaker and a wall switch to a row of downlights, with notes on cable size, RCD protection and switch types
The path from the DB box to the lights, simplified. Diagram: Dispatcher (file). Credit: drawn by Dispatcher, own work, licence held by Dispatcher.

ST's domestic wiring guideline (Garis Panduan Pendawaian Elektrik Pepasangan Domestik) lists light points as part of home wiring. The same list has cables, the main switch, a breaker or fuse, and an RCD.

An RCD is the safety switch that cuts power when current leaks to earth. See our RCD guide.

Cable comes next. In section 8.3, Jadual 8.2 of the guideline sets the minimum conductor size for a lighting or fan circuit at 1.5 mm2. A 13A socket circuit needs at least 2.5 mm2 in the same table.

These are minimums. Your contractor picks the cable that suits your home.

On protection, section 7.3 of the guideline has a table of RCD sensitivity. It says a lighting or fan circuit uses an RCD with a sensitivity of 100 mA or less, under Peraturan 36 of the Electricity Regulations 1994.

Before adding lights, ask the contractor to look at your DB box and the lighting circuit it feeds. Sockets are a different circuit. See our guide to adding a power point.

How are lights switched: one switch, two switches or more?

Your lights can sit on one switch, on a pair of two-way switches, or on two-way switches plus an intermediate switch in the middle. Tell your electrician which one you want.

The guideline shows example wirings for these in section 6.2(j), Rajah 6.6 to 6.10. They cover:

  • one light on a one-way switch
  • two lights on one switch
  • two lights on two switches
  • one light on a two-way switch
  • three lights on two-way plus intermediate switches

Those are drawings for contractors, not a how-to for you. Switch wiring is its own topic. See our guide to the two-way light switch.

Decide the layout with your electrician before the first opening is cut.

What should you tell the electrician before quotes?

Tell each electrician the same six things. Then the quotes cover the same job.

Checklist with six tick boxes: ceiling type, rooms and number of lights, switch type, indoor or outdoor, existing circuit and DB box, and a registered contractor
Six things to tell each electrician. Diagram: Dispatcher (file). Credit: drawn by Dispatcher, own work, licence held by Dispatcher.

Start with the ceiling. Say what it is, such as a false ceiling or a concrete one.

Name the rooms and a rough number of lights. See our guide to what affects an electrician's quote.

Say which switch layout you want, as in the section above.

Mention any light that goes outside, such as on a porch or in a car porch. The guideline's section 9.1(f)(iii) on lights says lights installed outside must be weatherproof and waterproof.

Have a photo of your closed DB box ready. It shows the contractor what is already there.

Last, ask for the contractor's registration with the Energy Commission. You can look it up on ST's public list of registered electrical contractors.

Dispatcher has not checked listed businesses' licences yet, so this check is yours. See our guide to checking an electrical contractor.

Can you swap a light yourself?

This page gives no do-it-yourself steps. ST's home wiring page sends consumers to a registered contractor for internal house wiring work, so treat a new or changed light as their job.

Dispatcher is not an emergency service and has no emergency line.

Parts matter too. The guideline says regulated electrical equipment and wiring accessories must carry the ST-SIRIM safety label.

It also says switches, socket outlets, plugs and ceiling roses used in uPVC conduit wiring must be the polycarbonate type. A ceiling rose is the round fitting that holds a hanging light, and uPVC conduit is the plastic pipe that holds the cable.

An aircond has its own circuit. See our aircond power point guide.

Get quotes on Dispatcher

Free for homeowners. Describe the job in one short form on Dispatcher.

Dispatcher does not do the work. Tell each contractor the six things above.

Get quotes

Sources

Frequently asked questions

Who should install downlights in a Malaysian home?

A contractor registered with the Energy Commission (ST). ST's home wiring page says consumers need to contact any registered electrical contractor for inspection and internal house wiring work. Dispatcher has not checked listed businesses' licences yet, so check ST's public list of registered electrical contractors yourself before you hire.

What cable does a lighting circuit use?

ST's domestic wiring guideline sets a minimum conductor size of 1.5 mm2 for lighting and fan circuits, against 2.5 mm2 for 13A socket circuits (section 8.3, Jadual 8.2). Those are minimums, not a shopping list. Your contractor sizes the actual cable for your home, so ask what they plan to use and why.

Does a lighting circuit need an RCD?

Yes. The guideline's section on RCD sensitivity says lighting and fan circuits use an RCD with a sensitivity of 100 mA or less. An RCD is the safety switch that cuts power when current leaks. Ask your contractor to check what protects your lighting circuit now, before adding lights.

Can downlights be controlled from two switches?

Yes, the guideline shows example wiring for a light on a two-way switch, and for three lights on two-way plus intermediate switches (Rajah 6.6 to 6.10). That lets you switch the same lights from two or more places. Tell your contractor which layout you want before any openings are cut.

Can I fit downlights outdoors?

Only with a fitting that is weatherproof and waterproof. ST's domestic wiring guideline says lights installed outside must be both (section 9.1(f)(iii)). A contractor decides which light and wiring suit your porch. Say early that the light goes outside, so every quote covers it.

How do I check my electrician is registered?

Search ST's public list of registered electrical contractors, which is on its ECOS site. See our guide to checking an electrical contractor. Dispatcher has not checked listed businesses' licences yet, so the check is yours. ST's home wiring page tells consumers to use a contractor registered with the Energy Commission.

Your next step

Written by the Dispatcher editorial team from the sources above. See how Dispatcher works.

Ready to compare electricians for your lights? Get quotes

Last updated: 24 November 2026